stoner_measurement.instruments.source_meter.TriggerModelConfiguration

class stoner_measurement.instruments.source_meter.TriggerModelConfiguration(trigger_source: TriggerSource = TriggerSource.IMM, trigger_count: int = 1, trigger_delay: float = 0.0, arm_source: TriggerSource = TriggerSource.IMM, arm_count: int = 1)[source]

Bases: object

Configuration for simple trigger and arm models.

Variables:
  • trigger_source (TriggerSource) – Source that advances the trigger layer. Defaults to IMM.

  • trigger_count (int) – Number of times the trigger layer executes per arm. Defaults to 1.

  • trigger_delay (float) – Delay in seconds inserted before each measurement trigger. Defaults to 0.0.

  • arm_source (TriggerSource) – Source that advances the arm layer. Defaults to IMM.

  • arm_count (int) – Number of times the arm layer executes. Defaults to 1.

arm_count: int = 1
arm_source: TriggerSource = 'IMM'
trigger_count: int = 1
trigger_delay: float = 0.0
trigger_source: TriggerSource = 'IMM'