stoner_measurement.plugins.monitor.magnet_controller.MagneticFieldMonitorPlugin¶
- class stoner_measurement.plugins.monitor.magnet_controller.MagneticFieldMonitorPlugin(parent=None)[source]¶
Bases:
MonitorPluginPublish live magnet-controller readings into the sequence value catalogue.
Use this monitor when you want the sequence to have access to live magnet information such as field, current, voltage, ramp rate, heater state, and stability. The selected quantities appear in the sequence value catalogue and can then be displayed, logged, plotted, saved, or used by other plugins.
In the configuration panel, choose which quantities should be reported.
The General tab sets the instance name and comment. Measurement selection and polling options are on Settings.
You can enable any combination of:
Field
Target field
Current
Voltage
Field rate
Target field rate
Heater
At target
Stable
The configuration tab presents these quantities as independent check boxes, allowing you to publish only the values needed by the rest of the sequence. The same tab also includes a force fresh poll option for cases where each read should actively request an updated hardware state from the controller engine instead of relying on cached values.
For more technical use, the selected parameters are exposed both via
read()/last_readingand as typed accessor methods on the instance itself (field(),target_field(),current(),voltage(),field_rate(),heater(),at_target(),stable()) so that they can be referenced directly in sequence scripts.- Variables:
report_field (bool) – When
True, the measured field is included in every reading.report_target_field (bool) – When
True, the target field is included in every reading.report_current (bool) – When
True, the magnet current is included in every reading.report_voltage (bool) – When
True, the magnet voltage is included in every reading.report_field_rate (bool) – When
True, the field rate of change is included in every reading.report_target_field_rate (bool) – When
True, the controller’s target field ramp rate is included in every reading.report_heater (bool) – When
True, the heater state is included in every reading.report_at_target (bool) – When
True, the at-target flag is included in every reading.report_stability (bool) – When
True, the stability flag is included in every reading.force_fresh_poll (bool) – When
True, every call toread()requests an immediate hardware poll from the engine rather than relying solely on the cached engine state.instance_name (str) – Inherited Python identifier for this instance in the Script tab and QtConsole.
comment (str) – Inherited optional note displayed beside this step.
sequence_engine (SequenceEngine | None) – Inherited owning engine and its live namespace; None while detached.
last_reading (dict[str, float]) – Inherited read-only access to the latest cached readings.
monitor_interval (int) – Inherited timer polling interval in milliseconds; initially 1000.
- Keyword Parameters:
parent (QObject | None) – Optional Qt parent object.
Examples
With a sequence instance named
magnetic_field_monitor, use the QtConsole to inspect or edit it before running. Substitute your instance name if different; result data reflects completed steps:magnetic_field_monitor.force_fresh_poll = False magnetic_field_monitor.last_reading
- at_target() float[source]¶
Return whether the magnet is at its target field.
- Returns:
1.0when at target or0.0otherwise.- Return type:
(float)
- config_widget(parent: QWidget | None = None) QWidget[source]¶
Return the configuration widget for this plugin.
- Keyword Parameters:
parent (QWidget | None) – Optional Qt parent widget.
- Returns:
Configuration widget with all plugin settings.
- Return type:
(QWidget)
Examples
>>> from qtpy.QtWidgets import QApplication >>> _ = QApplication.instance() or QApplication([]) >>> from stoner_measurement.plugins.monitor.magnet_controller import MagneticFieldMonitorPlugin >>> m = MagneticFieldMonitorPlugin() >>> w = m.config_widget() >>> w is not None True
- connect() None[source]¶
Ensure the engine is connected and start the polling timer.
- Raises:
RuntimeError – If no magnet controller is connected.
Examples
>>> from qtpy.QtWidgets import QApplication >>> _ = QApplication.instance() or QApplication([]) >>> from stoner_measurement.plugins.monitor.magnet_controller import MagneticFieldMonitorPlugin >>> m = MagneticFieldMonitorPlugin() >>> try: ... m.connect() ... except RuntimeError: ... pass
- property controller_features: frozenset[str]¶
Return controller feature flags required by this plugin.
- current() float[source]¶
Return the current magnet current in amps.
- Returns:
Magnet current in amps, or
math.nanwhen unavailable.- Return type:
(float)
- declared_outputs() PluginOutputs[source]¶
Declare configured outputs and their physical units together.
- disconnect() None[source]¶
Stop the polling timer; the shared engine is left running.
Examples
>>> from qtpy.QtWidgets import QApplication >>> _ = QApplication.instance() or QApplication([]) >>> from stoner_measurement.plugins.monitor.magnet_controller import MagneticFieldMonitorPlugin >>> m = MagneticFieldMonitorPlugin() >>> m.stop_monitoring() >>> m.disconnect()
- field() float[source]¶
Return the current magnetic field in tesla.
- Returns:
Magnetic field in tesla, or
math.nanwhen unavailable.- Return type:
(float)
- field_rate() float[source]¶
Return the field ramp rate in tesla per minute.
- Returns:
Field ramp rate in T/min, or
math.nanwhen unavailable.- Return type:
(float)
- heater() float[source]¶
Return the persistent-switch heater state.
- Returns:
1.0when the heater is on,0.0when it is off, ormath.nanwhen unavailable.- Return type:
(float)
- property quantity_names: list[str]¶
Ordered list of parameter keys returned by
read().Examples
>>> from qtpy.QtWidgets import QApplication >>> _ = QApplication.instance() or QApplication([]) >>> from stoner_measurement.plugins.monitor.magnet_controller import MagneticFieldMonitorPlugin >>> m = MagneticFieldMonitorPlugin() >>> "field" in m.quantity_names True
- read(*, force_poll: bool = False) dict[str, float][source]¶
Read the latest parameter snapshot from the engine.
By default retrieves the engine’s cached state without issuing additional hardware queries. When force_poll is
Truethe engine performs an immediate hardware poll and the freshly read state is used, making the call synchronous with the hardware.- Keyword Parameters:
force_poll (bool) – When
True, requests an immediate hardware poll from the engine before returning values. Defaults toFalse.- Returns:
Mapping of parameter name to current value. Returns
math.nanfor any parameter that cannot be obtained from the engine state.- Return type:
Examples
>>> from qtpy.QtWidgets import QApplication >>> _ = QApplication.instance() or QApplication([]) >>> from stoner_measurement.plugins.monitor.magnet_controller import MagneticFieldMonitorPlugin >>> m = MagneticFieldMonitorPlugin() >>> reading = m.read() >>> "field" in reading True >>> reading_forced = m.read(force_poll=True) >>> "field" in reading_forced True
- stable() float[source]¶
Return whether the magnetic field is stable.
- Returns:
1.0when stable or0.0otherwise.- Return type:
(float)
- target_field() float[source]¶
Return the current target magnetic field in tesla.
- Returns:
Target magnetic field in tesla, or
math.nanwhen unavailable.- Return type:
(float)
- to_json() dict[str, object][source]¶
Serialise plugin configuration to a JSON-compatible dict.
Examples
>>> from qtpy.QtWidgets import QApplication >>> _ = QApplication.instance() or QApplication([]) >>> from stoner_measurement.plugins.monitor.magnet_controller import MagneticFieldMonitorPlugin >>> m = MagneticFieldMonitorPlugin() >>> d = m.to_json() >>> d["report_field"] True
- property units: dict[str, str]¶
Mapping of parameter name to physical unit string.
Examples
>>> from qtpy.QtWidgets import QApplication >>> _ = QApplication.instance() or QApplication([]) >>> from stoner_measurement.plugins.monitor.magnet_controller import MagneticFieldMonitorPlugin >>> m = MagneticFieldMonitorPlugin() >>> m.units["field"] 'T' >>> m.units["current"] 'A'