Collecting, fitting and saving data¶
This walkthrough extends the basic measurement in Usage with a scan, selected scalar outputs, filtering, curve fitting, live plots, and data files. The same data-selection and saving controls are available for state sweeps. It is a guided user workflow. For the result schema use Trace data and output catalogues, for execution/reconfiguration use Sequence execution reference, and for implementing new steps use Writing sequence plugins.
A complete example¶
Download the scan, fit and save example
and load it with File → Open Sequence… on the Measurement tab.
Custom toolbar buttons can also load predefined sequences: if your installation
has a button for this workflow, clicking it opens the configured sequence.
Such buttons are configured locally and may differ between installations.
The downloadable example uses a hardware-free Counter scan with six values, 0 through 5, and the Dummy I-V trace. The simulated critical current changes with the scan value. It follows the acquisition/filter/fit/plot/save pattern of a field or temperature experiment without requiring a controller connection. The required User, Sample, and Project fields are already filled in with demonstration values.
The sequence tree is organised as follows:
details
scan (Counter)
iv (Dummy)
filter_ (Window Filter)
curve_fit (Curve Fit)
plot_raw (Plot Trace)
plot_filtered (Plot Trace)
plot_fit (Plot Trace)
plot_points (Plot Points)
save_traces (Save)
save_live (Save)
save_complete (Save)
Each scan point acquires a trace, processes it, fits the model, plots the
current results, and executes the child Save steps. The scan then appends its
collected row. After all six points, save_complete writes the finished
scan table. Choose a default data directory in Edit → Preferences… before
running: this example writes into a guide subdirectory there.
Completed example with six fitted-parameter points. The last I-V trace and fit use the bottom/left axes; the parameter points use the top and extra right-side axes.¶
Choosing what a scan or sweep collects¶
Select the parent scan or sweep and open its Data tab:
Enable Collect data to accumulate a table of scalar readings.
In Collected outputs, tick Include for each output you want to retain. Add measurement and processing steps first so their outputs appear; use Refresh output list after changing the available outputs.
Set each included output’s Role. In this example, collect
curve_fit:Ic,curve_fit:Rnand their_erruncertainties.scan:Valueis selected as the independent variable. Optionally enter a Label to use as its dataframe column header and trace channel name. Leave it blank to retain the output name (or the standardxcolumn for an independent variable). Labels must be unique and must not use the bookkeeping namesiteration,stageorstate.Keep Clear on start enabled for a fresh table on each execution of the scan. Disable it only when you intend to accumulate successive executions.
This is the parent state scan/sweep’s Data tab. A trace plugin’s Scan tab instead chooses the points within one acquired trace. To collect a trace’s scalar statistics, enable Report channel average and standard deviation outputs on that trace’s Scan tab, then select the new mean/std outputs in the parent’s Data table. Monitor readings and fitted parameters can be selected from the same catalogue.
Select numerical outputs independently of what is plotted or saved.
The unchecked scan:Index output is excluded from the selected readings.¶
Role |
Meaning |
|---|---|
|
Independent coordinate. Only one selected readback can have this role. |
|
Dependent measurement or fitted parameter. |
|
Additional data channel. |
|
Uncertainty channel. |
|
Auxiliary column retained without a primary plotting role. |
The Include checkbox determines whether a reading is collected; -
does not exclude it. Use all catalogue outputs selects all available
outputs and assigns automatic roles. Adjust the individual rows when you want
a smaller table or explicit roles.
By default the commanded scan/sweep value supplies x. Assigning x to
a readback instead uses that measured value and retains the commanded value
in a separate state column. The table also includes iteration and
stage bookkeeping columns. It is available directly as scan.data in
the trace selectors for plotting and saving; no conversion step is needed.
Collect filter is a Python condition applied in addition to the point’s
measurement flag. The default scan.meas_flag collects measurement points,
not travel-only points. Clear filter controls whether a requested clear
actually clears the table; its default is True. Replace scan in these
expressions with your own step’s instance name. Selecting outputs does not
execute their producers: place the measurement and fitting steps inside the
scan/sweep so their results are current when the row is collected.
Filtering and fitting a trace¶
Place Window Filter after the acquiring trace. On its Data tab choose
iv:Dummy and the voltage column. On Window, select the window type and
length. The example uses a symmetric nine-point hann window with
Normalise kernel enabled, giving a weighted local average without changing
the overall signal scale. Compare the filtered and raw traces when choosing
the length: smoothing can also change narrow features.
The filtered trace is published as filter_:filtered. The raw iv:Dummy
trace remains available for comparison and saving.¶
Place Curve Fit after the filter. On its Data tab choose
filter_:filtered and the column to fit. On Fit Function, define a
fit(x, p1, p2, ...) function or load one from the fitting function library.
The argument after x names each fitted parameter. An optional p0(x, y)
function computes the starting values; otherwise use the Initial row on
the Parameters tab. The example fits Ic and Rn:
def fit(I, Ic, Rn):
voltage = Rn * np.sign(I) * np.sqrt(np.abs(I**2 - Ic**2))
return np.where(np.abs(I) < Ic, 0.0, voltage)
def p0(I, V):
return 1e-6, 100.0
NumPy is available as np in the fit function’s runtime namespace.¶
On Parameters, set lower and upper bounds and inspect Initial used
and Fitted after a run. With p0 defined, Initial used shows the
values it returned. Calculate initial parameter trace and
Calculate best fit trace make comparison traces available to Plot Trace.
Values are from the last acquisition; they change across the scan.¶
Fitted scalar outputs such as curve_fit:Ic and curve_fit:Ic_err appear
in the value selectors and collection table. Trace outputs include
curve_fit:initial_fit and curve_fit:best_fit when enabled. A failed fit
is logged and produces NaN results, so check the fitted values and messages
before interpreting the plotted parameters.
Plot Points and Plot Trace¶
Command |
Input |
Behaviour |
|---|---|---|
Plot Trace |
An acquired trace, transformed trace, fitted curve, or collected table. |
Displays the table’s arrays; later calls update the same named series. |
Plot Points |
Current scalar outputs, such as scan value and fitted parameters. |
Appends one point per configured series each time the command executes. |
The example’s three Plot Trace commands display iv:Dummy,
filter_:filtered, and curve_fit:best_fit. These show the current
acquisition as the scan progresses. To display the completed collected table,
add a Plot Trace after the parent scan and select scan.data and its desired
column instead.
Place Plot Points inside the scan, after Curve Fit, so it appends the
parameters from the current acquisition. Choose XY as Plot form,
scan:Value as X value, and add Y series for curve_fit:Ic and
curve_fit:Rn. Set their labels, colours and point styles in the series
table. Add Y series adds another scalar output to the same command.
Separate axes let parameters with different units and scales share a plot.
This example uses top for the scan coordinate and Ic/Rn for the
additional Y axes, leaving bottom/left for the I-V traces.¶
Plotting and data collection are independent. Plot Points draws scalar readings; enabling Collect data retains those readings in a table that Save can write. Saving selects the underlying trace tables, not a screenshot of the plot.
Inspecting and replotting acquired traces¶
Open View → Show Data Manager after acquiring data. Each trace tab shows the acquired dataframe, with the trace’s channel names and units in the column headers. The All Traces tab shows each trace’s size and lets you select several traces for export.
On a trace tab, choose Plot Trace… from the toolbar or Trace menu. Select the columns for X data and Y data, then choose the display axes and optional title, colour, line and point settings. The initial selections follow the trace’s X and primary Y roles. Associated uncertainties follow the channels when you swap them. Use the Cartesian XY display for this workflow.
Click Send to Plot Window to add a series to the main Measurement plot. The Data Manager hides while the plot dialog is open, so you can move the dialog aside and use the Measurement plot. The dialog stays open so you can try another pair of columns from the same snapshot. Close it to return to the same trace tab in the Data Manager, or reopen it to use newly acquired rows.
Choose Save as TDI Format 2.0… or Save as NeXus/HDF5… from the toolbar or File menu. The active trace tab saves that trace. On All Traces, the same actions save the checked traces together. Exports use the most recent available data and write the file in the background.
Saving complete traces¶
Add Save after the steps that produce the required traces. Select the trace checkboxes, a File format, and a Path expression. Leave Save incrementally off for a complete snapshot on each execution.
save_traces writes the raw, filtered and best-fit I-V columns together
in one file per scan point. The collected scan table is unchecked here.¶
The expression f'guide/trace_{scan.ix:03d}.txt' gives
trace_000.txt, trace_001.txt, and so on. For a fixed filename, use a
quoted string such as 'guide/results.txt'. Relative paths use the default
data directory from Preferences; parent directories are created as needed.
Keep Never overwrite enabled to add a numeric suffix when a destination
already exists.
TDI Format 2.0 saves tab-delimited numerical columns and a metadata
snapshot, including the sequence configuration and evaluated outputs.
NeXus/HDF5 uses h5py, which is declared in the application dependencies;
the selector marks that writer unavailable if the module cannot be imported.
Use separate Save steps for full acquisition traces and the collected scan
table so their different row counts remain easy to interpret.
Saving a growing scan or sweep table¶
Inside the scan/sweep, add another Save step after acquisition and processing.
Select only scan.data, enable Save incrementally, and choose a stable
path such as 'guide/scan_live.txt'. Each execution updates the same file
with newly available rows. A path that changes on every iteration creates
separate destinations instead of one growing file.
The incremental command remembers its chosen destination for the current run, including any suffix selected to avoid overwriting an older file.¶
Important
Automatic collection occurs after all child steps for a scan/sweep
point. A Save child therefore sees rows collected on preceding iterations;
it does not yet see the current point’s row. In this six-point example,
scan_live.txt contains five rows when the loop ends.
For a complete file using only the sequence editor, put a separate Save
after the parent scan/sweep, select scan.data, and leave incremental
saving off. The example’s save_complete writes all six rows to
'guide/scan_complete.txt'.
To finish the same incremental file when developing a Python script, add one final call to the same Save instance after the generated loop has completed successfully, inside the outer try block, before its finally cleanup:
save_live() # after the scan loop, before the generated finally block
Do not rerun the whole sequence to flush the file: a new run clears the scan table when Clear on start is enabled and starts a new Save session. Calling the Save instance from the console after cleanup also requires a new connection/configuration, which starts a new save session; keep the final call before cleanup to retain the original incremental destination. The incremental setting tracks additional rows; use complete-trace saving for repeated acquisitions that replace a fixed-length table.
For a one-off check, use Run Selection… or Shift+F5 on the parent
scan so its acquisition, processing, plotting and Save children are included.
The following save_complete step is outside that selection: select it too
if you want the final complete snapshot. See Running selected steps.