Simulated Instruments¶
The application includes built-in simulated instrument drivers for development, testing, demonstrations, and training when laboratory hardware is not available.
For a first measurement, use the hardware-free trace in Usage; that example needs no controller connection. This page is the reference for testing the shared rig-control services with simulated drivers. See Controllers for their panels and Preferences and local resources if a subsystem is hidden.
The simulated drivers are ordinary instrument drivers and are discovered automatically by the instrument driver manager. They therefore exercise the same connection, engine, polling, charting, and configuration code paths as real hardware.
Available Simulated Drivers¶
Temperature Controller¶
SimulatedTemperatureController provides:
Four temperature inputs (A-D).
Two control loops.
PID parameter storage.
Setpoint ramping.
Heater output simulation.
Thermal lag between the control setpoint and measured temperature.
The controller maintains a programmed setpoint and an active control setpoint. When ramping is enabled, the active control setpoint moves towards the programmed setpoint at the configured ramp rate.
Magnet Controller¶
SimulatedMagnetController provides:
Magnetic field and current readback.
Field/current target setting.
Ramp-rate control.
Persistent-switch heater state.
Simulated output voltage during ramps.
The controller reports realistic operational states:
STANDBYRAMPINGAT_TARGET
Motor Controller¶
SimulatedMotorController provides angular position and target readback,
velocity and acceleration settings, absolute/relative moves, home positioning
and moving/at-target status. Motion progresses with elapsed time as readings
are requested. It is useful for exercising motor scan and monitor workflows,
but does not reproduce a particular stage’s travel limits or mechanics.
Pressure Gauge Controller¶
SimulatedPressureGaugeController supplies three pressure channels in mbar,
two stored relay setpoints and named interlock states. Its capability flags
disable remote gauge switching and pump control in the UI. Relay readback is
fixed rather than a simulation of threshold switching. Developer scripts can
exercise interlock handling with set_simulated_interlock(name, satisfied).
Mass-flow Controller¶
SimulatedMassFlowController supplies two flow channels, initially in sccm,
with setpoint, unit and range settings. Each actual-value read moves halfway
from the previous reading towards the requested setpoint. This is a simple
response model for flow controls and monitoring, not a calibrated gas model.
X-ray Diffractometer¶
SimulatedXrayDiffractometer implements the same abstract
XrayDiffractometer contract as the FTDI-backed legacy driver. It provides:
independent theta and 2-theta motion;
coupled
2-theta = 2 * theta + offsetmotion;exact hardware step quantisation;
scalar detector counts and count rates;
a deterministic synthetic powder-diffraction peak pattern.
Select Simulated in the X-ray panel’s instrument list. No address is required.
Using Simulated Instruments¶
The simulated drivers appear in the normal driver-selection controls used by the temperature, magnet, motor, pressure/flow and X-ray control panels.
No special configuration is required:
Open the relevant control panel.
Select a simulated driver from the driver list.
Connect as normal.
Use the panel exactly as you would with physical hardware.
Because the simulations are ordinary instrument drivers, they are useful for:
User-interface development.
Testing engine behaviour.
Demonstrating application features.
Training new users.
Reproducing issues without laboratory hardware.
Limitations¶
The simulations are intentionally simplified and are not intended to model every aspect of real hardware.
Examples of simplifications include:
Idealised thermal and magnetic behaviour.
Simplified voltage and heater models.
No communication failures.
No automatic reproduction of hardware-specific fault conditions. Explicit simulated interlock changes exercise only that particular software path.
The goal is to provide realistic application behaviour rather than a detailed physical model.